Sorted Category:
Patient range: Adult, pediatric, neonate
NIBP Measurement method: Oscillometric
NIBP Measurement range: 0 kPa – 38.67 kPa (0 mmHg – 290 mmHg)
NIBP Measurement mode: Arm Measurement
Temperature Range: 37°C to 42°C
Temperature Accuracy: ± 0.5°C
Warm-up Time: < 45 s (20°C to 36°C)
Power Consumption: 250 VA
Temperature Range: 37°C to 42°C
Temperature Accuracy: ± 1.0°C
Warm-up Time: < 45 s (20°C to 36°C)
Power Consumption: 80 VA
Display: 12.1” LCD display
Ultrasound frequency: 1024 (1 ± 10%) kHz
Max output intensity: < 10 MW/cm2
FHR measurement range: 30 bpm ~ 240 bpm
Display: 7-inch screen
Waveform: Biphasic
Manual with Sync mode: 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules
AED mode: Auto analyze and charge x 3 with programmable auto energy level selection.
Waveform: Biphasic
Energy Sequence: 150 J, 200 J
Analysis Time: 9 seconds
Audio Indications: 20 distinct voice instructions
Display: OLED 160 x 128 dot matrix display
Storage: Built-in TF card storage for up to 2 GB
Standard Sensitivity: 10 mm/mV ± 5%
Sensitivity Shift: ≤ ± 10%
Control System: Air-temp control, Skin-temp control & Humidity control
Display: LED display
Air Temperature Control range: 25°C ~ 37°C (Override : 37°C ~ 39°C)
Baby Temperature Control range: 25°C ~ 37°C (Override : 37°C ~ 39°C)
Control System: Air-temp control & Skin-temp control
Display: LED display
Air Temperature Control range: 25°C ~ 37°C (Override : 37°C ~ 39°C)
Baby Temperature Control range: 25°C ~ 37°C (Override : 37°C ~ 39°C)
Control System: Air-temp control
Display: LED display
Air Temperature Control range: 25°C ~ 37°C
Baby Temperature Control range:
Channel: Single channel infusion
Volume (VTBI): 1 ml ~ 9999.9 ml ( 0.1 ml increment)
Accuracy: Flow rate: ≤ ± 3 % Mechanical: ≤ ± 2 %
KVO Rate: 1 ml/h (1 ml/h ~ 300 ml/h) 3 ml/h (greater than 300 ml/h)
Channel: Single channel infusion
Infusion Volume: 0 ml ~ 9999 ml ( 0.1ml increment)
Infusion Rate: 0.01 ml/h ~ 1200 ml/h (0.01ml/h increment)
KVO Rate: 0.01 ml/h – 5 ml/h
Tidal Volume: 20 ml ~ 500 ml
Standard Ventilation Mode: VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH
Application: Adult/ Pediatric Invasive
Pressure Range: 5 mbar ~ 80 mbar
Tidal Volume: 10 ml ~ 300 ml
Standard Ventilation Mode: CMV, IMV, CPAP, Manual
Application: Pediatric
Inspiratory Flow: 3 L/min ~ 20 L/min
Tidal Volume: 20 ml ─ 2500 ml
Configurations: Trolley or Ceiling Pendant
Respiratory Rate: 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV) 4 bpm ─ 100 bpm ( VCV/PCV/PRVC)
Psupport: 0 kPa ─ 6 kPa
Control System: Microprocessor based temperature control system
Control Modes: Preheat, Manual and Skin-temp mode
Manual : Heater output: 0-100%, 10% increments
Skin-temp : Control range: 25 °C ~ 37 °C
Vital Parameters:
Type A Type B Type C 4 Parameters (NIBP,SpO2, PR, Temp) 3 Parameters (SpO2, PR, Temp) 3 Parameters (NIBP, SpO2, PR)
Display: 240 x 320 dot matrix colour TFT
NIBP Measurement range: Adult: 30-255 mmHg Paediatric: 30-160 mmHg
NIBP Mode: Auto, Manual, STAT
Vital Parameters: 3 Parameters (SpO2 (with PR), NIBP, & 1-channel TEMP)
NIBP Measurement range: Systolic Adult 50 ~ 265 mmHg Child 25 ~ 135 mmHg Diastolic Adult 15 ~ 220 mmHg Child 12 ~ 110 mmHg MAP Adult 25 ~ 245 mmHg Child 18 ~ 120 mmHg
NIBP Mode: Manual, Auto
NIBP Parameters: Sys, Dia, MAP
Standard Parameter: 5‐lead ECG, RESP, HR, NIBP, SpO2(F‐5), 1‐TEMP, PR
Patient Groups: Neonate, Pediatric, Adults
Trace: 9 waveform (ECG,SpO2, RESP)
ECG Lead Mode: 5–lead (R, L, F, N, C) for leads I, II, III, V, aVR, aVF, aVL
Light Source: 8 Blue LED lights
Wavelength: 450 to 475nm
LED Lamp-life: 1,00,000 hours
Intensity Control: Low : 25 ~ 35 μW /cm2/nm High : 35 ~ 55 μW /cm2/nm
Type: Adult
Stroke volume: 800 ml
Resuscitator volume: 1630 ml
Bag reservoir volume: 2000 ml
Type: Pediatric
Stroke volume: 350 ml
Resuscitator volume: 680 ml
Bag reservoir volume: 1600 ml
Type: Neonatal
Stroke volume: 150 ml
Resuscitator volume: 250 ml
Bag reservoir volume: 600 ml
KVO Rate: 0.1 – 5ml/h (steps : 0.1ml/h)
Injection Compliance: Adaptable for 5 syringe sizes
Preset Volume Range: 0.1 ml – 1999.9 ml
Occlusion System: 3-level alarming system
Channel: Single channel infusion
Volume (VTBI): 0 ml – 9999 ml
Injection Compliance: Adaptable for 6 syringe sizes
Accuracy: ≤ ±2 %
Channel: Dual channel infusion
Volume (VTBI): 0.1 ml – 1999.9 ml
Injection Compliance: Adaptable for 10 syringe sizes
Accuracy: ≤ ± 3 %
Tidal Volume: 0 ml – 1500 ml
Gas Supply: O2, 0.28 to 0.6 MPa
Ventilation Modes: A/C, SIMV, SPONT, Manual, VCV+SIGH
Respiratory Rate: 4 bpm – 40 bpm (SIMV) 4 bpm – 99 bpm (A/C)
Enquiry